The high performance thin-layer chromatographic method of daucosterol in Momordica charantia L. was developed by use of chloroform-acetate ester-acetone-acetate acid-distilled water-pyridine ( 3 : 6 : 6 : 1 : 0.9 : 0.1 ) on silica gel HPTLC G60 plate, The Rf value of daucosterol was 0.70. The calibration curve was linear ( r =0. 9953 ) in the range of 200 - 1000 ng for daucosterol. The average recovery of daucosteral was 100.56%. The results showed this method for determinatinn of daucosterol in the extracts of Momordica charan...